Atmospheric Electric Field Lightning Early-Warning Instrument
Lightning Monitoring and Early-Warning Device

EFW-L1

Atmospheric Electric Field Lightning Early-Warning Instrument

Sense electric-field changes and warn of lightning risk earlier

The EFW-L1 Atmospheric Electric Field Lightning Early-Warning Instrument directly measures changes in the atmospheric electric field before and after lightning events. Designed for continuous long-term operation, one station monitors within a 20-kilometre range and provides 5 to 30 minutes of warning lead time. Multiple stations can be networked for wider-area warning.

20km Monitoring Range
5–30min Warning Lead Time
0~±100kV/m Electric Field Range
10V/m Resolution

CORE CAPABILITIES

Sense electric-field changes and warn of lightning risk earlier

01

Continuous Atmospheric Electric-Field Monitoring

Direct measurement of atmospheric electric-field changes before and after lightning provides continuous observations for thunderstorm assessment and early warning.

02

Electric-Field Jump Recognition

Electric-field jump recognition captures rapid changes associated with lightning activity for timely risk identification.

03

Networked Electric-Field Warning

Multiple ground electric-field instruments can be networked, with a multi-station warning model extending regional coverage and assessment capability.

04

24/7 Unattended Operation

The instrument supports continuous unattended operation and can use AC power or a 12 V DC solar-power supply for outdoor monitoring.

TECHNICAL DATA

Full Specifications

Electric Field Range 0 to ±100 kV/m
Detection Distance 20 km
Resolution 10 V/m
Measurement Error ±3%
Sampling Rate 10/s to 0.1/s
Warning Lead Time 5–30 min
Communication Rate 1200 bps
Power Supply AC 220 V or DC 12 V (solar power)
Power Consumption ≤8 W
Grounding Resistance <10 Ω
Insulation Resistance ≥2 MΩ
MTBF ≥3000 h
MTTR ≤30 min
Operating Mode 24/7 unattended operation
Operating Temperature -30°C to +65°C
Operating Humidity 0–100%
Storage Temperature -35°C to +70°C
Storage Humidity 0–100%
Wind Resistance Up to Level 12
Field Equipment Electric-field sensor and support column
Outdoor Unit Connection cables and outdoor power control enclosure
Data Processing Data-processing computer and software

DOWNLOADS

Downloads

Downloads will be enabled when approved brochures are available.

Want to learn more about this product?

Contact us for product solutions, application guidance and technical materials.